| Board power supply | 24Vcc +-15% | |
| Cell power supply | 4 V dc per cell (1 cell of 350 Ω or 700 Ω) protected against short circuit | |
| Power assumption | 0.6W with 350 Ohm cell | |
| Output | 0 to +5V (-5/+5V) with load ≥ 2 kW | |
| Input sensitivity | Standard 2 mV/V, 1mV/V R3: 50 Ω | |
| Dimensions | 45mm x 20.5mm x 10mm | |
| Connections | Welded wires | |
| Cell connection | With 4 wires | |
| Storage temperature | - 10 °C / + 50 °C (14 °F / 122 °F) | |
| Operating temperature | - 20 °C / + 60 °C (- 4 °F / 140 °F) | |
| Linearity | 0.02% | |
| Thermal stability | 30 ppm/°C | |
| Zero adjustment | ± 10% full scale through multi-turn trimmer | |
| Gain adjustment | ±10% of full scale using multi-turn trimmer | |
| Analog Filter | 100 Hz | |
General precautions to be followed in the installation and assembly of load cells: