Weight Transmitters with direct connection of one ore more load cells and a wide range of outputs for an easy integration in every industrial and automation system. Comfortable and immediate installation on DIN bar and/or OMEGA bar.

TENSION CONTROLLER

Click on the image to enlarge

Transmitter RDT-01 Transmitter RDT-01 Drawing Transmitter RDT-01 Mounting

Technical specifications

Power supply24 V dc ± 10% (option linked to output relays)
Max power consumption170 mA
Operating temperature0 °C / + 50 °C - 32 °F / 122 °F (85% humidity without condensation)
Storage temperature-20 / +50°C (-4 / +122°F)
DisplayGraphic LCD 128 x 64 pixels, blue background with white lettering; backlit
Keyboard6-button membrane keyboard
Overall dimensions95 x 95 x 80 mm / 3.7 x 3.7 x 3.1 in
Case materialABS self-extinguishing
ConnectionsRemovable screw terminal blocks
Input sensitivity≤ 1 μV
Linearity0.001% of full scale
Temperature deviation0,003% of full scale/°C
Digital filter50 Hz
Number of weight decimalsFrom 0 to 3 decimals

For complete and up-to-date technical specifications please refer to the datasheet you can download here

Download PDF datasheet

Load cell mounting

General guidelines for installing and mounting load cells:

  • Respect the direction in which forces are applied to the load cells
  • Do not exceed the temperature limits shown on the rating plate
  • Do not remove the labels from the cells
  • Protect cables properly with sheaths or cable ducts
  • Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
  • Do not weld on the mechanical structure once the cells are in place
  • Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
  • When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
  • Protect the cells from dust build-up with suitable covers