Power supply24 V dc ± 10% (option linked to output relays)
Max power consumption170 mA
Operating temperature0 °C / + 50 °C - 32 °F / 122 °F (85% humidity without condensation)
Storage temperature-20 / +50°C (-4 / +122°F)
DisplayGraphic LCD 128 x 64 pixels, blue background with white lettering; backlit
Keyboard6-button membrane keyboard
Overall dimensions95 x 95 x 80 mm / 3.7 x 3.7 x 3.1 in
Case materialABS self-extinguishing
ConnectionsRemovable screw terminal blocks
Input sensitivity≤ 1 μV
Linearity0.001% of full scale
Temperature deviation0,003% of full scale/°C
Digital filter50 Hz
Number of weight decimalsFrom 0 to 3 decimals
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means