Transmitter RDT-01
Download PDF datasheetWeight Transmitters with direct connection of one ore more load cells and a wide range of outputs for an easy integration in every industrial and automation system. Comfortable and immediate installation on DIN bar and/or OMEGA bar.
TENSION CONTROLLER
Click on the image to enlarge
Technical specifications
| Power supply | 24 V dc ± 10% (option linked to output relays) |
|---|---|
| Max power consumption | 170 mA |
| Operating temperature | 0 °C / + 50 °C - 32 °F / 122 °F (85% humidity without condensation) |
| Storage temperature | -20 / +50°C (-4 / +122°F) |
| Display | Graphic LCD 128 x 64 pixels, blue background with white lettering; backlit |
| Keyboard | 6-button membrane keyboard |
| Overall dimensions | 95 x 95 x 80 mm / 3.7 x 3.7 x 3.1 in |
| Case material | ABS self-extinguishing |
| Connections | Removable screw terminal blocks |
| Input sensitivity | ≤ 1 μV |
| Linearity | 0.001% of full scale |
| Temperature deviation | 0,003% of full scale/°C |
| Digital filter | 50 Hz |
| Number of weight decimals | From 0 to 3 decimals |
For complete and up-to-date technical specifications please refer to the datasheet you can download here
Download PDF datasheetLoad cell mounting
General guidelines for installing and mounting load cells:
- Respect the direction in which forces are applied to the load cells
- Do not exceed the temperature limits shown on the rating plate
- Do not remove the labels from the cells
- Protect cables properly with sheaths or cable ducts
- Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
- Do not weld on the mechanical structure once the cells are in place
- Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
- When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
- Protect the cells from dust build-up with suitable covers