Cookie Consent by Free Privacy Policy website

Shear beam load cell TS16


Download PDF

Shear beam load cells for weighing tanks, silos, hoppers, load control of cranes, winches, lifting systems, automation etc..

Shear beam load cell

Upon request with ATEX o IECEx certification


Zoom Click to enlarge image

Shear beam load cell TS16 Shear beam load cell TS16 Schema
IECEX ATEX

Technical Specifications

MaterialStainless steel
Nominal load10, 20, 25, 50, 100 kg
Limit load150 % F.S.
Breaking load300 % F.S.
Supply voltageVcc 15 Max
Output2 mV/V
Output tollerance0,1 % F.S.
Zero tollerance1 % F.S.
Linearity0,03 % F.S.
Hysteresis0,03 % F.S.
Reapeatability0,03 % F.S.
Input resistance380-386 ohm
Output resistance350-353 ohm
Insulation resistance>= 2000 Mohm
Creep (30 Minutes)0,03 % F.S.
Thermal compensation-10 / +40°C (14 / +104°F)
Operating temperature-20 / +70°C (-4° / +158°F)
Temperature deviation zero0,003 % F.S. / °C
Temperature deviation full scale0,002 % F.S. / °C
Protection classIP 67
Standard cable length10 m – 6 x 0,30 (shield not connected to the load cell body)
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

TypeSHIELDED CABLE 6C R7 PUR 6X0,35
Length10 m (body lead cell not connected shield)
Red+ IN
Blue- IN
White+ REF
Black- REF
Yellow+ OUT
Green- OUT
Connections  Shear beam load cell TS16

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means