Universal load cells for fixed installation machines, for scales, containers, automatic machines etc..
Universal load cell
Upon request with ATEX or IECEx certification
 Click to enlarge image
 Click to enlarge image
 
                                        	 
                                      
		 	 
                                             
                    				| Material | Stainless Steel | 
| Nominal load | 500, 1000, 2500, 5000, 10000, 20000 kg | 
| Limit load | 150 % F.S. | 
| Breaking load | 300 % F.S. | 
| Supply voltage | Maximum 15 V dc | 
| Output | 2 mV/V | 
| Output tollerance | 0,1 % F.S. | 
| Zero tollerance | 1 % F.S. | 
| Linearity | 0,03 % F.S. | 
| Hysteresis | 0,03 % F.S. | 
| Reapeatability | 0,03 % F.S. | 
| Input resistance | 700-710 ohm | 
| Output resistance | 700-705 ohm | 
| Insulation resistance | >= 2000 Mohm | 
| Creep (30 Minutes) | 0,03 % F.S. | 
| Thermal compensation | -10 / +40°C (14 / +104°F) | 
| Operating temperature | -20 / +70°C (-4 / +158°F) | 
| Temperature deviation zero | 0,003 % F.S. / °C | 
| Temperature deviation full scale | 0,002 % F.S. / °C | 
| Protection class | IP 67 | 
| Standard cable length | 5 m – 4 x 0,25 (shield not connected to the load cell body) | 
 
        	| Type | SHIELDED CABLE 4C R5 PUR 4X0,25 | 
| Length | 5 m (body lead cell not connected shield) | 
| Red | + IN | 
| Black | - IN | 
| Green | + OUT | 
| White | - OUT | 
General precautions to be followed in the installation and assembly of load cells: