ROLL LOAD CELL

Features: Load cell for straight supports. Insensitive to stresses in 2 axes excluding the measurement one. Protection against overloads.

Applications: measure of tension sectors, tessil, paper, rubber, nylon, metallic laminated, weigh etc.

Click on the image to enlarge

Roll load cells RT320 Roll load cells RT320 Drawing Roll load cells RT320 Mounting

Technical specifications

MaterialAluminum/Stainless steel
Nominal load10, 15, 20, 30, 50, 75, 100 kN
Limit load200 % F.S.
Breaking load500 % F.S.
Nominal load deflection0,10 mm
Supply voltageMaximum 18 V dc
Sensitivity1 mV/V
Output tollerance0,1 % F.S.
Zero tollerance1 % F.S.
Linearity0,1 % F.S.
Hysteresis0,03 % F.S.
Reapeatability0,15 % F.S.
Input resistance350-360 ohm
Output resistance350-353 ohm
Insulation resistance>= 2000 Mohm
Creep (30 Minutes)0,03 % F.S.
Thermal compensation-10 / +40°C (14 / +104°F)
Operating temperature-20 / +70°C (-4 / +158°F)
Temperature deviation zero0,003 % F.S. / °C
Temperature deviation full scale0,002 % F.S. / °C
Protection classIP 65
ConnectionPanel connector CR2R-07APNS
Standard cable lengthLoose female connector CR2P-07ASNS-10, connection cable 6 x 0,35 (length to be defined)

For complete and up-to-date technical specifications please refer to the datasheet you can download here

Download PDF datasheet

Connections

TypeCONNECTOR MIL 4P IT3106A-14S
Length5 - 10 m (shield not connected to the cell body)
Pin A- IN
Pin B- OUT
Pin C+ OUT
Pin D+ IN
OptionalCONNECTOR 4P 4-20 mA S154
Length5 - 10 m (shield not connected to the cell body)
Pin A4 mA
Pin C20 mA

Load cell mounting

General guidelines for installing and mounting load cells:

  • Respect the direction in which forces are applied to the load cells
  • Do not exceed the temperature limits shown on the rating plate
  • Do not remove the labels from the cells
  • Protect cables properly with sheaths or cable ducts
  • Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
  • Do not weld on the mechanical structure once the cells are in place
  • Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
  • When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
  • Protect the cells from dust build-up with suitable covers