Cookie Consent by Free Privacy Policy website Skip to content

Gicam weight indicators are weight indicator devices connected to load cells. We have multifunction displayers for weighing and dosing, for bridge weighing, with load limiter. Portable displayers are available in comfortable briefcases. We have panel mounting, portable, DIN and OMEGA bar mounts, analog indicators and touch screens indicators. IP65 products are available with dust protection. Gicam indicators support industrial communication protocols like PROFIBUS, PROFINET, MODBUS and more.

Indicator

Click on the image to enlarge

Indicator WIN13

Technical specifications

Power supply230 / 115 V ac, 50 / 60 Hz – option 12 V dc
Max power consumption15 VA
IsolationClass II
Installation CategoryCategory II
Operating temperature-10 / +40°C (14 °F / 104°F) Humidity maximum 85% non-condensing
Storage temperature-20 / +50°C (-4 / +122°F)
DisplayNumeric 7-digit, 7-segment LED (h 14 mm)
Led7 3 mm indicator LEDs
Keyboard14 membrane buttons with buzzer
Overall dimensions144 x 72 x 120 mm / 5.67 x 2.83 x 4.72 in (l x h x p) (DIN43700)
MountingPanel mount
Case materialSelf-extinguishing Noryl (UL94 V1)
Protection levelIP 54
ConnectionsRemovable screw terminal blocks 5.08 pitch (power supply pitch7.5), serial ports on 9-pole SUB-D plug
Power supply load cells5 V dc / 120 mA (maximum 8 cells with 350 Ω in parallel) protected against short-circuit
Input sensitivity≥ 0,02 μV
Linearity< 0.01% of full scale
Temperature deviation<0,0003% of full scale/°C
Internal resolution24 bit
Weight resolutionUp to 600.000 counts (6.000 if legal)
Measuring range-3.9 mV/V - +3.9 mV/V
Weight acquisition frequency6 Hz - 160 Hz
Digital filter0.2 Hz - 50 Hz
Output rate5 Hz - 50 Hz
Number of weight decimalsfrom 0 to 4 decimal digit
Zero / FS CalibrationAutomatic (theoretical) or executable through buttons
Analog output in tension0 – 10 V / 0 – 5 V
Resolution16 bits
CalibrationDigital through buttons
Impedance≥ 10 kΩ
Linearity0.03% full scale
Temperature deviation0.001% full scale / °C
Analog output under current0 - 20 mA / 4 - 20 mA
Resolution16 bits
CalibrationDigital through buttons
Impedance≤ 300 Ω
Linearity0.03% full scale
Temperature deviation0.001% of full scale/°C
Logical output6 relays (NO contact) maximum 115 V ac / 30 V dc, 0.5 A each
Logical input8 opto-isolated at 12 / 24 V direct current PNP
Additional logic outputs2 external boards of 8 relays as above (optional)
Serial portCOM1: Rs232c half duplex COM2: Rs422/Rs485 half duplex
Max. cable length15m (Rs232c) and 1000m (Rs422 and Rs485)
Serial protocolsASCII, Stampanti Alfapanel, EPSON, Modbus
Baud rate1200, 2400, 4800, 9600, 19200, 38400, 115000 selectable
Program code memory128 Kbytes FLASH re-programmable on board via RS232
Data memory8 Kbytes expandible up to 36 Kbytes
Optional fiscal memory1 Mbytes (up to 160.000 weighing saved)
Calendar clockOn motherboard with buffer battery
Conforms to standardsEN61000-6-2, EN61000-6-3, EN61010-1, EN45501

For complete and up-to-date technical specifications please refer to the datasheet you can download here

Download PDF datasheet

Connections

Type9 pin Sub-D
LengthND
1NC
2RS232 Rx
3RS232 Tx
4RS422 TX+
5GND
6RS422 TX-
7RS422 RX-
8RS232 CTS
9RS422 RX+
TypeTerminal block 3P (pitch 7.5)
LengthND
1230V~ Line
2230V~ Neutral
3GND
TypeTerminal block 11P (pitch 5.08)
LengthND
1Output 1
2Output 2
3Common output
4Output 3
5Output 4
6Output 5
7Output 6
8Common output
9+12V Encoder
10Encoder Input
110 encoder
TypeTerminal block 15P (pitch 5.08)
LengthND
1- Exc. Load cell
2+ Exc. Load cell
3+ Load cell Sense
4- Load cell Sense
5- Signal load cell
6+ signal load cell
7Input 1
8Input 2
9Input 3
10Input 4
11Input 5
12Input 6
13Common input
14+ Analog output (input 7)
15- Analog output (Input 8)
Connections Indicator WIN13

Load cell mounting

General guidelines for installing and mounting load cells:

  • Respect the direction in which forces are applied to the load cells
  • Do not exceed the temperature limits shown on the rating plate
  • Do not remove the labels from the cells
  • Protect cables properly with sheaths or cable ducts
  • Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
  • Do not weld on the mechanical structure once the cells are in place
  • Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
  • When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
  • Protect the cells from dust build-up with suitable covers