WEIGHT VISUALIZER for load cells
Indicator of weight with input for cargo cells or input 0-10V or 4-20mA.
Numerical Display to 6 characters/figures, height 60 mm, container in stainless steel and watertight logons.
Configuration and calibration from remote control, serial trasmition Rs232, Rs485. RF868Mhz extern interface (optional).
Download installation and usage manual ![]()
Click to enlarge image
| Power supply | 230 - Opz. 115 Vac 50/60 Hz | |
| Max power consumption | 10 W | |
| Operating temperature | -10 / +40°C (14 °F / 104°F) Humidity maximum 85% non-condensing | |
| Storage temperature | -20 / +50°C (-4 / +122°F) | |
| Display | High efficiency 6-digit numerical LED and wide viewing angle, reading distance up to 50 feet | |
| Reading distance | Till at 15 m | |
| Visualized data | Weight acquired from cells or analogue input 0-10V/4-20 mA, alphanumeric indications/programming menu | |
| Functions remote control | Tare entry / cancellation, zero scale, serial transmission current weight, configuration and calibration | |
| Overall dimensions | 320 x 110 x 90 mm /12.6 x 4.3 x 3.5 in (l x h x p) | |
| Mounting | Wall-mounted with 4 external side holes Ø 6 mm with center distance 340 x 80 mm (l x h) | |
| Case material | Stainless steel protected against dust | |
| Protection level | IP 65 | |
| Connections | Waterproof circular connectors with conductor wiring with screw terminal | |
| Power supply load cells | 5 V dc / 120 mA (maximum 8 cells with 350 Ω in parallel) protected against short-circuit | |
| Linearity | < 0.01% of full scale | |
| Temperature deviation | <0,0003% of full scale/°C | |
| Internal resolution | 24 bit | |
| Weight resolution | Up to 60,000 divisions on the load capacity | |
| Measuring range | -1.5 mV/V - +3.5 mV/V | |
| Weight acquisition frequency | 6 Hz - 25 Hz | |
| Digital filter | 0.2 Hz - 25 Hz | |
| Number of weight decimals | from 0 to 3 decimal digit | |
| Communication ports | Rs232c / Rs485 standard | |
| Max. cable length | 15m (Rs232c) and 1000m (Rs485) | |
| Serial protocols | ASCII + custom protocols | |
| Baud rate | From 1200 to 115200 selectable | |
| Remote control | 4-key remote control for configuration and operational commands | |
| Options | External 868 MHz RF interface, Ethernet protocol, Profibus protocol | |
| Conforms to standards | EN61000-6-2, EN6100-6-3, EN61010-1 | |
| Type | J1 5 poles serial female |
| Length | ND |
| 1 | GND + Shield |
| 2 | RS232 Rx |
| 3 | RS485 - |
| 4 | RS485 + |
| 5 | RS232 Tx |
| Type | J2 5 poles male load cell |
| Length | ND |
| 1 | + Exc. Load cell |
| 2 | + signal load cell |
| 3 | - Signal load cell |
| 4 | - Exc. Load cell |
| 5 | Shield |
| Type | J3 7 poles male optional outputs |
| Length | ND |
| 1 | Out 1 NA |
| 2 | Out 1 NC |
| 3 | Out 2 NA |
| 4 | Out 2 NC |
| 5 | Out 3 NA |
| 6 | Out 3 NC |
| 7 | Common output |
General precautions to be followed in the installation and assembly of load cells: