Accessories ACME1
Download PDF datasheetMounting accessories, allowing easy use of compression, bending, shear cells, providing the ideal solution in order to concentrate the weight on the load cell.
For ME cells from 250 kg to 10 t
Click on the image to enlarge
Technical specifications
| Material | Stainless steel |
|---|---|
| Nominal load | 250 kg ÷ 10 t |
For complete and up-to-date technical specifications please refer to the datasheet you can download here
Download PDF datasheetLoad cell mounting
General guidelines for installing and mounting load cells:
- Respect the direction in which forces are applied to the load cells
- Do not exceed the temperature limits shown on the rating plate
- Do not remove the labels from the cells
- Protect cables properly with sheaths or cable ducts
- Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
- Do not weld on the mechanical structure once the cells are in place
- Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
- When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
- Protect the cells from dust build-up with suitable covers