Accessories ACTS5
Download PDF datasheetMounting accessories, allowing easy use of compression, bending, shear cells, providing the ideal solution in order to concentrate the weight on the load cell.
For TS2 - TS4 - TS5 - TS5/F cells.
Stainless steel
Click on the image to enlarge
Technical specifications
| Material | Stainless steel |
|---|---|
| Type of installation | For cells TS2 – TS4 – TS5 – TS5F |
For complete and up-to-date technical specifications please refer to the datasheet you can download here
Download PDF datasheetLoad cell mounting
General guidelines for installing and mounting load cells:
- Respect the direction in which forces are applied to the load cells
- Do not exceed the temperature limits shown on the rating plate
- Do not remove the labels from the cells
- Protect cables properly with sheaths or cable ducts
- Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
- Do not weld on the mechanical structure once the cells are in place
- Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
- When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
- Protect the cells from dust build-up with suitable covers