Converter S215 -5 +5 Volt
Download PDF datasheetTechnical specifications
| Board power supply | 24Vcc +-15% |
|---|---|
| Cell power supply | 4 V dc per cell (1 cell of 350 Ω or 700 Ω) protected against short circuit |
| Power assumption | 0.6W with 350 Ohm cell |
| Output | 0 to +5V (-5/+5V) with load ≥ 2 kW |
| Input sensitivity | Standard 2 mV/V, 1mV/V R3: 50 Ω |
| Dimensions | 45mm x 20.5mm x 10mm |
| Connections | Welded wires |
| Cell connection | With 4 wires |
| Storage temperature | - 10 °C / + 50 °C (14 °F / 122 °F) |
| Operating temperature | - 20 °C / + 60 °C (- 4 °F / 140 °F) |
| Linearity | 0.02% |
| Thermal stability | 30 ppm/°C |
| Zero adjustment | ± 10% full scale through multi-turn trimmer |
| Gain adjustment | ±10% of full scale using multi-turn trimmer |
| Analog Filter | 100 Hz |
For complete and up-to-date technical specifications please refer to the datasheet you can download here
Download PDF datasheetLoad cell mounting
General guidelines for installing and mounting load cells:
- Respect the direction in which forces are applied to the load cells
- Do not exceed the temperature limits shown on the rating plate
- Do not remove the labels from the cells
- Protect cables properly with sheaths or cable ducts
- Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
- Do not weld on the mechanical structure once the cells are in place
- Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
- When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
- Protect the cells from dust build-up with suitable covers