Roll load cells R104F
Download PDF datasheetROLL LOAD CELL
Features: Possibility to rotate the cell 360 °. Low thickness. For bearings external diam. 28, 32, 35, 40, 42 mm, for new and existing machines.
Applications: for the measure of tension tape, tessil, paper, metal laminated, plastic, rubber, flexographic printing presses and for photografic development machinery, etc.
Click on the image to enlarge
Technical specifications
| Material | Stainless steel/Aluminium |
|---|---|
| Nominal load | 150, 250, 350, 500, 750, 1000 N |
| Limit load | 500 % of full scale |
| Breaking load | 2000 % of full scale |
| Nominal load deflection | 0,10 mm |
| Supply voltage | Maximum 18 V dc |
| Sensitivity | 1 mV/V |
| Output tollerance | 0,1 % F.S. |
| Zero tollerance | 1 % F.S. |
| Linearity | 0,1 % F.S. |
| Hysteresis | 0,03 % F.S. |
| Reapeatability | 0,1 % F.S. |
| Input resistance | 350-360 ohm |
| Output resistance | 350-353 ohm |
| Insulation resistance | >= 2000 Mohm |
| Creep (30 Minutes) | 0,03 % F.S. |
| Thermal compensation | -10 / +40°C (14 / +104°F) |
| Operating temperature | -20 / +70°C (-4 / +158°F) |
| Temperature deviation zero | 0,003 % F.S. / °C |
| Temperature deviation full scale | 0,002 % F.S. / °C |
| Protection class | IP 54 / IP 65 |
| Connection | Panel male connector UTS08E4P |
| Standard cable length | Loose female connector UTS6JC8E4S, connection cable 4 x 0,25 (length to be defined) |
For complete and up-to-date technical specifications please refer to the datasheet you can download here
Download PDF datasheetConnections
| Type | CONNECTOR M12 RSFM5 MALE |
|---|---|
| Length | 5 m (shield not connected to the cell body) |
| Pin 4 | - IN |
| Pin 2 | - OUT |
| Pin 3 | + IN |
| Pin 1 | + OUT |
Load cell mounting
General guidelines for installing and mounting load cells:
- Respect the direction in which forces are applied to the load cells
- Do not exceed the temperature limits shown on the rating plate
- Do not remove the labels from the cells
- Protect cables properly with sheaths or cable ducts
- Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
- Do not weld on the mechanical structure once the cells are in place
- Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
- When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
- Protect the cells from dust build-up with suitable covers