Indicator WIN6 A+B

Download PDF datasheet

LOAD LIMITER

Limitation of the detected load through alarm and pre-alarm levels.

Overload control with double-security system by connecting two units.

Limitation of load (single and sum) for weighing systems up to 4 points, by connecting more units.

Load cell fail alarm and Set-up and calibration via keyboard and display board removable.

Click on the image to enlarge

Indicator WIN6 A+B Indicator WIN6 A+B Drawing

Technical specifications

Power supply12 – 24 V ac ± 15 %
Average consumption4 W
IsolationClass II
Operating temperature-10 / +50 °C (14 / 122 °F) Humidity Maximum 85% non-condensing
Storage temperature-20 / +60°C (-4 / +140°F)
DisplayNumeric 6-digit, 7-segment LED (h 14mm)
Led5 3 mm indicator LEDs of which 3 indicate the relay outputs status
Keyboard4 mechanical keys
Overall dimensions115 mm x 93 mm x 65 mm / 4.53 x 3.66 x 2.56 in (l x h x p)
MountingSupport for DIN rail or OMEGA bar
Case materialPolyamide 6.6 UL 94V-0, self-extinguishing
ConnectionsRemovable screw terminals. Pitch screws terminal blocks 5.08 mm
Load cell input featuresMax 4
Input sensitivity≥ 0,02 μV
Linearity< 0.01% of full scale
Temperature deviation< 0.001% of full scale/C°
Internal resolution24 bit
Measuring range-3.9 mV/V - +3.9 mV/V
Digital filter0.1 Hz – 10 Hz, selectable
Output rate10 Hz
Number of weight decimalsFrom 0 to 3 decimals
Zero / FS CalibrationExecutable through buttons
Cell cable interruption checkAlways present
Analog output in tensionOptional: ± 10 V / ± 5 V
Resolution16 bits
CalibrationDigital through buttons
Impedance≥ 10 kΩ
Analog output under currentOptional: 0 - 20 mA / 4 - 20 mA
Resolution16 bits
CalibrationDigital through buttons
Impedance≤ 300 Ω
Logical input1 optically isolated dry contact
Logical output alarm2 relay out (24 V DC/AC, one NO contact), 1 relay out (24 V DC/AC, one changeover contact), relay contact capacity 0.5 A
Serial portRs232 / Rs485 (alternative)
Max. cable length15m (Rs232) and 1000m (Rs485)
Baud rateUp to 115 kb/s (default 9600 b/s)
Program code memory32 Kbytes
Data memory2 Kbytes
Conforms to standardsCompliance to EMC norms: EN61000-6-2, EN61000-6-3, Compliance electric safety: EN 61010-1

For complete and up-to-date technical specifications please refer to the datasheet you can download here

Download PDF datasheet

Connections

Type6 Pin pull-out terminal block
LengthND
1- Exc. Load cell
2+ Exc. Load cell
3+ Load cell Sense
4 - Load cell Sense
5- Signal load cell
6+ signal load cell
Type18 Pin pull-out terminal block
LengthND
7RS232 Tx
8RS232 Rx
9RS232 GND
10RS485 +
11RS485 -
12Input (Dry contact)
13Input (Dry contact)
14+ ~ (Power supply 12 to 24 Vdc/Vac +/- 15%)
15- ~ (Power supply 12 to 24 Vdc/Vac +/- 15%)
16Analog output + (V or mA)
17Analog output -
18Common Relay Output 1
19N.O. contact Relay Output 1
20Common Relay Output 2
21N.O. contact Relay Output 2
22Common Relay Output 3
23N.O. contact Relay Output 3
24N.C. contact Relay Output 3
Connections Indicator WIN6 A+B

Load cell mounting

General guidelines for installing and mounting load cells:

  • Respect the direction in which forces are applied to the load cells
  • Do not exceed the temperature limits shown on the rating plate
  • Do not remove the labels from the cells
  • Protect cables properly with sheaths or cable ducts
  • Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
  • Do not weld on the mechanical structure once the cells are in place
  • Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
  • When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
  • Protect the cells from dust build-up with suitable covers