Cookie Consent by Free Privacy Policy website Skip to content

Gicam weight indicators are weight indicator devices connected to load cells. We have multifunction displayers for weighing and dosing, for bridge weighing, with load limiter. Portable displayers are available in comfortable briefcases. We have panel mounting, portable, DIN and OMEGA bar mounts, analog indicators and touch screens indicators. IP65 products are available with dust protection. Gicam indicators support industrial communication protocols like PROFIBUS, PROFINET, MODBUS and more.

Indicator

Click on the image to enlarge

Indicator WIN9

Technical specifications

Power supply24 Vcc ± 15%
Max power consumption5 W
IsolationClass II
Installation CategoryCat. II
Operating temperature-10 / +40 °C (85% humidity without condensation)
Storage temperature-20 / +50 °C
DisplayNumeric 6 digit, 7 segments red LED's display (h 14 mm)
Led5 indicator leds (3 mm)
Keyboard4 mechanical keys
Overall dimensions96 mm x 48 mm x120 mm (l x h x p)
MountingPanel mount (cutout 91 mm x 44 mm)
Case materialSelfextinguish Noryl (UL 94 V1)
Protection levelIP 54
ConnectionsTerminal blocks, pitch 5.08 mm
Power supply load cells5 Vcc / 90mA (max six 350 ohm parallel load cells) short circuit proof
Input sensitivity0.02 µV min
Linearity< 0.01% full scale
Temperature deviation< 0.001% full scale / C°
Internal resolution24 bit
Weight resolutionUp to 60,000 divisions on the load capacity
Measuring range-3.9 mV/V - +3.9 mV/V
Weight acquisition frequency6 Hz - 50 Hz
Digital filterfrom 0.1 Hz to 25 Hz selectable
Number of weight decimalsfrom 0 to 3 decimal digit
Zero / FS CalibrationAutomatic (data sheet calibration) or via keyboard
Analog output in tensionOptional: ± 10 V / ± 5 V
Resolution16 bits
CalibrationBy push-buttons
Impedance10Kohm Min
Linearity0.03% full scale
Temperature deviation0.001% full scale / °C
Analog output under currentOptional: 0 - 20 mA / 4 - 20 mA
Resolution16 bits
CalibrationBy push-buttons
Impedance300 ohm max
Linearity0.03% full scale
Temperature deviation0.001% full scale / °C
Logical output2 opto-isolated max 24Vdc / 60 mA each
Logical input2 opto-isolated 24Vcc PNP (requires external power supply)
Serial portRs232c / Rs422 / Rs485 half duplex
Max. cable length15m (Rs232c) and 1000m (Rs422 and Rs485)
Serial protocolsASCII, Modbus
Baud rate2400 / 9600 / 19200 / 38400 / 115000
Program code memory64 Kbytes FLASH on board reprogrammable by RS232
Data memory2 Kbytes
Conforms to standardsEN50081-1, EN50082-2, EN61010-1

For complete and up-to-date technical specifications please refer to the datasheet you can download here

Download PDF datasheet

Connections

TypeTerminal block 12P (pitch 5.08)
LengthND
1+ 24 Vcc Power supply
2- 24 Vcc Power supply
3Analog current output 0-20mA/4-20mA Max 300 ohm
4Analog vltage output 0-5V/ 0-10V min 10Kohm
5Negative analog output Voltage/Current
6RS232 Tx
7RS232 Rx
8GND
9RS485 TX+
10RS485 TX-
11RS485 RX+
12RS485 RX-
TypeTerminal block 12P (pitch 5.08)
LengthND
13Output 1
14Output 2
15Common output
16+ Input 1
17+ Input 2
18Common input
19- Exc. Load cell
20+ Exc. Load cell
21+ Load cell Sense
22- Load cell Sense
23- Signal load cell
24+ signal load cell
Connections Indicator WIN9

Load cell mounting

General guidelines for installing and mounting load cells:

  • Respect the direction in which forces are applied to the load cells
  • Do not exceed the temperature limits shown on the rating plate
  • Do not remove the labels from the cells
  • Protect cables properly with sheaths or cable ducts
  • Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
  • Do not weld on the mechanical structure once the cells are in place
  • Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
  • When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
  • Protect the cells from dust build-up with suitable covers